1) Switch on power source switch, indicated light not on.
Reasons: a. power source switch broken.
b. fuse ACFU fusing.
2) Switch on power source switch, indicated light on, but not outputting ultrasonic.
Reasons: a. transducer and ultrasonic power board conneting abnormally.
b. fuse ACFU fusing.
c. ultrasonic power generator broken.
d. transducer broken.
3) Direct current fuse DCFU fusing.
Reasons: a. commutate bridge or power tube burnt down.
b. transducer broken.
4) Switch on power source, outputting ultrasonic, but cleaning result not good.
Reasons: a. position of cleaning liquid in cleaning trough incorrect.
b. ultrasonic frequency adjusting incorrectly.
c. temperature of liquid in cleaning trough too high.
d. wrong cleaning liquid.
|